Data centre efficiency is typically measured by Power Usage Effectiveness (PUE)—the ratio of the total energy consumed by a data centre to the energy used by its IT equipment. With the spiralling cost of energy, 2bm remains focused on using innovative technologies to decrease a data centre’s PUE factor significantly.

With no predicted price cap on commercial energy tariffs, there is an ongoing focus on significantly decreasing data centre PUE factors.

There are few silver linings to the cloud of current spiralling energy bills. However, the quick ROI on the CapEx required to maintain the resilience of the installations of mission-critical data centre equipment could be deemed one!

Innovative technologies are now available that can significantly decrease a data centre’s PUE factor. However, as there is no predicted price cap on commercial tariffs going forward, focusing on energy-efficient data centres has taken on even greater importance.

As the plant approaches its end of life, replacing legacy equipment is a necessity. In the data centre environment, this process must be well-planned and seamless to maintain active equipment uptime.

With this in mind, and with the rising global temperatures, more and more of our clients are asking us to ensure that the new equipment is not only future-proofed but can cope with ambient temperatures greater than 45ºC.

Stuart Everitt, 2bm’s Data Centre Design and Build Manager, commented: “2bm prides itself on being a true vendor-neutral company, which means we can utilise the most up-to-date and innovative cooling technologies we have had experience installing.”

“This allows us to fully explore the market for the correct design solution to meet individual project needs and constraints.”

During the hottest day on record in the UK, 2bm undertook an Integrated Systems Test on a new data centre installation.

Located on the 7th and 8th floors of a London-based medical research facility and with outside temperatures soaring to 41ºC, we accrued some extremely interesting test data!

We are delighted to report that our predicted outcomes were achieved. Based upon our design parameters, the installation ‘did what it said on the tin’! This included a full load, day one test at 125kW.

2bm’s data centre design combines an adiabatic cooling plant and rear door heat exchangers. Even during the hottest period of the 24-hour test, the room temperature maintained the desired 26ºC, and the cooling water flow temperatures remained steady at 23ºC, providing a highly successful and reassuring test result.

Contact our data centre experts to learn more or to discuss options for your data centre facility.